Omron F3SJ-A series User Manual page 89

Safety light curtain
Hide thumbs Also See for F3SJ-A series:
Table of Contents

Advertisement

F3SN replacement correspondence table (F3SN mounting holes can be used without modification)
•When replacing F3SN-
F3SN
Model name
Protective height
F3SN- 0187P25
187
F3SN- 0217P25
217
F3SN- 0232P25
232
F3SN- 0247P25
247
F3SN- 0262P25
262
For lengths greater than the F3SN- 0277P25:
Subtract a number, ranging from 7 to 22, from the F3SN's 4-digit number and apply it as the F3SJ's 4-
digit number, and then replace with the standard brackets included with the product.
[Selection example] F3SN-A0322P25 becomes F3SJ-A0300P25-TS (replace with standard brackets)
The formula shown above is recommended for mounting in the center of a mounting hole. If a
mounting position is unmatched, another mounting hole must be drilled.
- The protective height becomes shorter by 7 to 22mm.
- Replace with outward-facing mounting of F39-LJ5 when you want to set the detection surface height to be same as
the F3SN.
However, the F39-LJ5 and intermediate mounting brackets cannot be mounted simultaneously, so set the protective
height to 600mm or less.
P25 with F3SJ-A
P25-TS
Replacement F3SJ
Model name
-
-
F3SJ-A0260P25-TS
260
F3SJ-A0260P25-TS
260
F3SJ-A0260P25-TS
260
F3SJ-A0260P25-TS
260
Wiring/Installation
Replacement method
using F39-LJ5
Protective height
-
Inward-facing mounting
Inward + outward-facing
mounting
Inward + outward-facing
mounting
Outward-facing mounting
E
F3SJ-A
71
User's Manual