Indicator Display Patterns; Internal Indicator For Basic System - Omron F3SJ-A series User Manual

Safety light curtain
Hide thumbs Also See for F3SJ-A series:
Table of Contents

Advertisement

Indicator Display Patterns

1. Incident light level
indicator
2. Error mode
indicator
3. Power indicator (Green)
4. Lockout indicator (Yellow)
5. External device monitoring indicator (Green)
[Muting input 1 indicator]
6. Test indicator(Green)
[Muting input 2 indicator]

Internal Indicator for Basic System

Shown below are indication statuses of F3SJ's internal indicator when you purchased.
No.
1
Incident light level
indicator
2
Error mode indicator
3
Power indicator
4
Lockout indicator
5
External device
monitoring indicator
6
Test indicator
7
OFF-state indicator
8
ON-state indicator
9
10
Emitter
LEVEL
5
LEVEL-5 (Green)
4
LEVEL-4 (Green)
LEVEL-3 (Orange)
3
LEVEL-2 (Orange)
2
LEVEL-1 (Orange)
1
C
ERROR- C (Red)
ERROR-B (Red)
B
ERROR-A (Red)
A
ERROR
POWER
LOCKOUT
EDM
TEST
0
ON/
Indicators
Blinking
LEVEL-1 to 5
ON
ERROR-A to C ON/
Blinking
POWER
ON
LOCKOUT
Blinking
EDM
ON
TEST
Blinking
OFF
ON
Blinking
ON
ON
Overview and Specifications
Receiver
LEVEL
5
LEVEL-5 (Green)
4
LEVEL-4 (Green)
3
LEVEL-3 (Orange)
LEVEL-2 (Orange)
2
LEVEL-1 (Orange)
1
C
ERROR-C (Red)
ERROR-B (Red)
B
ERROR- A (Red)
A
ERROR
*1
7. OFF-state indicator (Red)
OFF
8. ON-state indicator (Green)
ON
9. Not used (Green)
[Muting error indicator]
10. Not used (Green)
[Test indicator]
20
A set of square brackets, [ ], indicates
name of an indicator under muting system.
*1 This label comes with the F39-CN6 key
cap for muting. Affix this label when a
keycap is used.
Description
Indication status of LEVEL-1 to 5 shows the incident light level
status of the F3SJ.
Turns ON or blinks only when the F3SJ enters lockout, and the
cause of the error is indicated by the status of ERROR-A to C
indicators.When F3SJ are series-connected, the error mode
indicator lamps turn ON or blink according to the details of each
error. Affix the error mode label (included) near the F3SJ to
allow for quick troubleshooting when errors occur. For details of
the error mode, see "Chapter 6 Troubleshooting".
Turns ON while the power is ON.
Blinks when in lockout.
Turns ON when an input is given to external device monitoring
input.
Blinks when external test is being performed.
Turns ON when safety outputs are OFF.
Blinks when in lockout.
Turns ON when safety outputs are ON.
1. Incident light
level indicator
2. Error mode
indicator
F3SJ-A
7
User's Manual
E

Hide quick links:

Advertisement

Table of Contents
loading