Wiring/Installation
5.
Fasten to equipment.
Attach top/bottom mounting bracket (1) to the equipment, wall surface, etc. If you are using an
intermediate mounting bracket for side mounting, also attach the side-mounting intermediate bracket
to the equipment, wall surface, etc. After the F3SJ is mounted, securely tighten the mounting screws
(M3x10) that were lightly tightened in step 2 above.
Backside mounting
6.
Adjust the beams.
Move the F3SJ from side to side to align it to a center position where the 5 lamps of the incident light
level indicator are turned ON. After each screw is securely tightened after beam adjustment, make
sure that the 5 lamps of the incident light level indicator are turned ON.
Mounting is complete.For adjustment of beams and tightening torque, see "Adjustment Procedure" in
the next page.