1.
Connect an emitter cable (F39-JC
2.
Connect a receiver cable (F39-JC
(black).
3.
Connect the 0V line of the power supply directly to the protective earth (PE).
To ensure proper wiring, check that the color of the cable matches the color of the connector's resin cover (emitter: grey,
receiver: black). Failure to do so may result in damage to the F3SJ. Incorrect wiring can be prevented by matching the
colors.
Cable with Connector on One End (F39-JC A, sold separately)
M12 Waterproof connector
Set model name
F39-JC3A
F39-JC7A
F39-JC10A
F39-JC15A
F39-JC20A
Internal wiring diagram (F39-JC A-L, F39-JC A-D)
Connected to connection cable and
Cable with connectors on both ends
2
1
7
8
6
4
5
Female
Twisted pair wires are white and red, brown and blue, green and yellow, and grey and pink
F3SJ-A
86
User's Manual
39.5
Insulated vinyl round cable dia. 6.6, shielded
8-wire (4-pair) (Cross section of conductor: 0.3mm
For emitter
F39-JC3A-L
Grey cable
F39-JC7A-L
F39-JC10A-L
F39-JC15A-L
F39-JC20A-L
1
White
2
Brown
3
Green
4
Yellow
3
5
Grey
6
Pink
7
Blue
8
Red
Shield
-L, grey, sold separately) to the emitter's connection cable (grey).
-D, black, sold separately) to the receiver's connection cable
L
F39-JC3A-D
F39-JC7A-D
F39-JC10A-D
F39-JC15A-D
F39-JC20A-D
White
Brown
Green
Yellow
Communication line (+)
Grey
Communication line (-)
Pink
Blue
Red
(Unit: mm)
/insulator diameter: dia. 1.15mm)
2
For receiver
Black cable
3000
7000
10000
15000
20000
Emitter
Receiver
Safety output 2
N.C
+24V DC
+24V DC
Test input
Control output 1
Reset input
Auxiliary output 1
Communication line (+)
Communication line (-)
0V
0V
External device
N.C
monitoring input
Shield
L (mm)