When Using the F39-JJR3W Series Connection Cable for Extension (sold separately)
1.
Remove the caps from the primary sensor. (driver comes with key cap for muting)
2.
Use the F39-JJR3W series connection cable for extension to connect them.
3.
When changing the connection distance between the F3SJ, connect a F39-JC B Cable with
connectors on both ends (sold separately).
Enlarged view of emitter
power supply connector side
Emitter power supply
- When attaching a cable or a cap, tightly fasten the screws (M2, in 4 places, recommended torque: 0.15N m). Failure to
do so may cause the cable/cap to come loose, leading to deterioration of the protective functions.
- Attaching/detaching of a cap or a series-connection cable may cause misalignment of rubber grommet in a connector
assembly.
Press the grommet to the bottom of the connector and attach the connector F3SJ again.
p.57
Emitter power supply
connector side
3. 3.
F39-JC B
2. 2.
F39-JJR3W
1. 1.
Cap
connector side
Wiring/Installation
Receiver power supply
connector side
3. 3.
F39-JC B
Enlarged view of receiver
power supply connector side
2. 2.
F39-JJR3W
1. 1.
Cap
Receiver power supply
connector side