System Configuration and Functions
Wiring Diagrams
Using a photoelectric switch as a muting sensor
Timing Chart
Muting sensor A1
Muting sensor B1
Muting state
Muting lamp
(external indicator)
F3SJ Unblocked
/Blocked
Safety output
*1 The value is applied to a single sensor. Values for connected sensors are:
# of connections
Single
2 connected
3 connected
•T1min: Muting input time limit (minimum value)
This is set to 0.03 sec., the minimum value for the input time difference between muting input 1 and 2.
A muting error occurs when the input time difference between muting input 1 and 2 is less than this
value.
•T1max: Muting input time limit (maximum value)
This is set to 3 sec., the maximum value for the input time difference between muting input 1 and 2.
•T2: Muting time limit
This is set to 60 sec., the muting function continuation time. When this muting state exceeds this time,
muting is released.
F3SJ-A
34
User's Manual
B1
Reflector
A1, B1: Regressive reflection
photoelectric switch
- PNP Output
- ON when Interrupted
Reflector
A1
F3SJ
ON
OFF
T1min to T1max
ON
OFF
0.15s max. *1
Enabled
Disabled
Blinking
OFF
Unblocked
Blocked
ON
OFF
*1 Value (s)
0.15
0.26
0.29
Using an N.O contact type switch as a muting sensor
A1
B1
T3(0.1s) max.
T3(0.1s) max.
T2 max.
A1, B1: N.O contact type switch
+ 24 V DC
Power
supply
0 V