Omron F3SJ-A series User Manual page 28

Safety light curtain
Hide thumbs Also See for F3SJ-A series:
Table of Contents

Advertisement

Overview and Specifications
Indicators
Mutual interference prevention
function
Series connection
Test function
Safety-related functions
Connection method
Protection circuit
Ambient temperature
Ambient humidity
Ambient light intensity
Insulation resistance
Dielectric strength voltage
Degree of protection
Vibration resistance
Shock resistance
Connection cable, Series connection
cable (F39-JJR L, JJR3W)
Extension cable (F39-JC A,
JC B,JC C)
Material
F3SJ-A
10
User's Manual
F3SJ-A
Emitter
Incident light level indicators (green LED x 2, orange LED x 3): ON based on the amount of
incident light
Error mode indicators (red LED x 3): Blink to indicate error details
Power indicator (green LED x 1): ON while power is ON
Lockout indicator (yellow LED x 1): Blinks when in lockout
External device monitoring indicator (muting input 1 indicator), Test indicator (muting input 2
indicator) (green LED x2): ON/Blink according to function
Receiver
Incident light level indicators (green LED x 2, orange LED x 3): ON based on the amount of
incident light
Error mode indicators (red LED x 3): Blink to indicate error details
OFF-statet indicator (red LED x 1): ON when safety outputs are OFF/ Blinks when in lockout
ON-state indicator (green LED x 1): ON when safety outputs are ON
Muting error indicator, Test indicator (green LED x 2): ON/Blink according to function
Interference light avoidance algorithm
Time division emission by series connection
- Number of connections: Up to 3 sets
- Total number of beams: Up to 240
- Maximum cable length between 2 sets of sensors: 15m
Lockout occurs when:
- Number of connected sensors or total number of beams of them exceed the limits described
above
- Other sensor than -TS type is attached to the series connection
- Self-test (After power ON, and during operation)
- External test (light emission stop function by test input)
- External device monitoring
- Muting (Includes override functions. F39-CN6 key cap for muting is required)
Connector method (M12, 8-pin)
Output short-circuit protection, and power supply reverse polarity protection
During operation: -10 to 55°C (without freezing), During storage: -30 to 70°C
During operation: 35 to 85%RH (no condensation), During storage: 35 to 95%RH
Incandescent lamp: receiving-surface light intensity of 3,000 Ix max., Sunlight: receiving-
surface light intensity of 10,000 Ix max.
20MΩ or higher (500VDC)
1, 000VAC, 50/60Hz, 1min
IP65 (IEC60529)
Malfunction: 10 to 55Hz, Multiple amplitude of 0.7mm, 20 sweeps each in X, Y, and Z directions
Malfunction: 100m/s
Dia. 6 mm, 8-wire (0.15mm
Dia. 6.6 mm, 8-wire (0.3mm
Allowable bending radius of R36mm.
(To extend a cable, use an equivalent or higher-performance cable (twisted-pair wire) , and do
not use the cable in the same duct as that for high-voltage cables or power cables)
For details about extension lengths (power cable length) p.15
For details about twisted pair wire (single connector cable)
Casing (including metal parts on both ends): Aluminum, zinc die-cast
Cap: ABS resin
Optical cover: PMMA resin (acrylic)
Cable: Oil resistant PVC
P20-TS
, 1,000 times each in X, Y, and Z directions
2
x 8) with braided shield, Allowable bending radius R5mm
2
2
x 4P, conductor resistance 0.058 ohm/m), with braided shield,
F3SJ-A
P25-TS
p.86