System Configuration and Functions
2.
The muting sensor outputs are turned ON (muting inputs are HIGH) and the safety function of the F3SJ
is disabled.
When muting sensors A1 and B1 are turned ON in this order, the muting function is enabled. In this
state, the safety function of the F3SJ is disabled.
3.
The muting sensor outputs are turned ON (muting inputs are HIGH) and the safety function of the F3SJ
is disabled.
The F3SJ is blocked but the safety function is disabled by the muting function, and safety outputs 1
and 2 are turned ON.
F3SJ-A
32
User's Manual
Hazardous zone
F3SJ
B1
Workpiece
A1
F3SJ
Hazardous zone
F3SJ
B1
Workpiece
A1
F3SJ
Reflector
Reflector
Reflector