Dr 19 External Speed - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

8.19

DR 19 External speed

If the SIWAREX module is not to determine the belt speed because the current speed is
available externally, e.g. in a controller, it can be passed on to the SIWAREX via DR 19. The
current material flow rate can then be calculated.
Procedure
● Enter a value in data record DR 19
● Transfer the data record to the scale
Table 8- 17
Assignment of data record 19
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which application the
data record belongs to
Version identifier
Information about current data record
version
External speed
The externally determined speed can be
value
sent to the scale.
Reserve 1
Reserve
Reserve 2
Reserve
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Scale parameters and functions of the belt scale
Type
L Rw
Default Min.
USHORT
2 r
19
USHORT
2 r
16
USHORT
2 r
104
USHORT
2 r
1
FLOAT
4 rw
0
SHORT
2 rw
0
USHORT
2 rw
0
8.19 DR 19 External speed
Max.
Register
-
-
1602
-
-
1603
-
-
1604
1
65635 1605
-
-
1606
0
-
1608
0
-
1609
119