Dr 8 Date And Time - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

8.10

DR 8 date and time

The weighing module has its own hardware clock. The current date and time are specified by
or read from data record DR 8. The clock is buffered with a capacitor and can continue
operating for up to approximately 70 hours without a supply voltage. If you are using the
Modbus protocol, data record DR 48 must be used for the date and time.
Procedure
● Set the date and time
● Transfer the data record to the scale
Table 8- 8
Assignment of data record 8
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which
application the DR belongs to
Version identifier
Information about current data
record version
Date and time
SIMATIC DTL format
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Scale parameters and functions of the belt scale
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
DTL
12
rw
8.10 DR 8 date and time
Default
Min.
Max.
8
-
-
20
-
-
104
-
-
1
1
65635
DTL#1970
-
-
-01-01-
00:00:00.0
Register
1341
1342
1343
1344
1345
105

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents