Current Master Totalizer (S1); Current Main Totalizer (S2); Totalizer 3 (S3), Totalizer 4 (S4), Totalizer 5 (S5); Totalizer 6 (S6) - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

Scale parameters and functions of the belt scale
8.25 DR 33 Totalizers
8.25.1

Current master totalizer (S1)

This totalizer contains the total of conveyed material since commissioning of the scale. The
master totalizer can only be reset by loading the factory settings.
8.25.2

Current main totalizer (S2)

The totalizer contains the quantity of material transported since the last memory reset. The
operating total must be logged in the case of trade scales requiring verification (available
soon). You can reset the total using command 670.
8.25.3

Totalizer 3 (S3), totalizer 4 (S4), totalizer 5 (S5)

The totalizers respond like the main totalizer S2. In the case of trade scales requiring
verification, these totals can be reset without logging.
You can reset the totals individually to 0 using the following commands:
● S3 using command 671
● S4 using command 672
● S5 using command 673
8.25.4

Totalizer 6 (S6)

A special property of totalizer 6 is that it remains active even following the command "Stop
totalizing (652)", and therefore indicates the total amount. You can therefore carry out
material tests or calibrate the scale, for example, without recording the "transported material"
(calibration weight, test chain) into the balance.
You can reset the total S6 using command 674.