Dr 10 Load Cell Parameters - Siemens SIWAREX WP241 Manual

Electronic weighing system
Table of Contents

Advertisement

8.12

DR 10 load cell parameters

The parameters of the analog load cells must be checked prior to the automatic calibration
and modified if necessary. Only the parameters identified by bold font and asterisk (*) need
be entered.
Procedure
● Check the parameters and modify them as required
● Transfer the data record to the scale
● Calibrate the scale
Table 8- 10
Assignment of data record 10
Variable
Data record number
Length
Application
Version identifier
Number of load cells
(Page 108)
1)
50/60 Hz toggling
(Page 108)
Reserve 1
Load cell characteristic
value (Page 108)
1)
Rated load of a load
cell (Page 108)
1)
Reserve
Reserve
Reserve 2
Reserve 3
Reserve 4
Parameter for calculation of calibration points with theoretical calibration
1)
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Note
Contains no. of data record
Data record length
information
Information about which
application the DR belongs
to
Information about current
data record version
Number of analog load cells USHORT
50/60 Hz toggling
Reserve
Characteristic value of the
load cell (n) [mV/V], the
mean value is used if there
is more than one cell.
Rated load of a load cell
Reserve
Reserve
Reserve
Reserve
Reserve
Scale parameters and functions of the belt scale
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
2
rw
USHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
FLOAT
4
rw
SHORT
2
rw
USHORT
2
rw
FLOAT
4
rw
8.12 DR 10 load cell parameters
Default
Min.
Max.
10
-
-
38
-
-
104
-
-
1
1
65635
1
1
6
0
0
1
0
0
0
2
> 0.1
10
60
-
-
0
-
-
0
-
-
0
-
-
0
-
-
0
-
-
Register
1400
1401
1402
1403
1404
1405
1406
1407
1409
1411
1413
1415
1416
1417
107