8.25

DR 33 Totalizers

Data record DR 33 contains the actual values of the totalizers.
Totalizing becomes active when the minimum belt load for the totalizer (parameter in DR6)
has been exceeded. Command 652 can be used to stop all totalizers except S6. Command
651 starts totalizing again.
Table 8- 23
Assignment of data record 33
Variable
Note
Data record
Contains no. of data record
number
Length
Data record length information
Application
Information about which application the
data record belongs to
Version identifier
Information about current data record
version
Current master
Master totalizer (S1) since commissioning
totalizer (S1)
of the scale
(Page 134)
Current main
Current main totalizer (S2)
totalizer (S2)
(Page 134)
Reserve
-
Totalizer 3 (S3),
Totalizer S3
totalizer 4 (S4),
Totalizer S4
totalizer 5 (S5)
Totalizer S5
(Page 134)
Totalizer 6 (S6)
Totalizer S6
(Page 134)
Reserve
-
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Scale parameters and functions of the belt scale
Type
L
Rw
Default
USHORT
2
r
33
USHORT
2
r
44
USHORT
2
r
104
USHORT
2
r
1
DOUBLE
8
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
FLOAT
4
r
0
8.25 DR 33 Totalizers
Min.
Max. Register
-
3514
-
3515
-
3516
3517
3518
3522
3524
3526
3528
3530
3532
3534
133