8.27 DR 38 Process state extended

8.27
DR 38 Process state extended
The data record contains scale-specific parameters.
Procedure
● Read data record DR 38
● Display/analyze the required tags
Table 8- 25
Assignment of data record 38
Variable
Data record number
Length
Application
Version identifier
Counter zeroing
Counter initial zero
calibration
Counter span calibration
Drag indicator (belt load)
Reserve
Current initial zero offset
(belt load)
Current initial zero offset
(in % of nominal load)
Reserve
Reserve
Reserve
Reserve
Reserve
136
Note
Contains no. of data record
Data record length
information
Information about which
application the data record
belongs to
Information about current
data record version
Number of implemented
zeroing procedures, recording
of manual and automatic
zeroing procedures (is reset
when loading the factory
settings)
Number of implemented initial
zero calibration procedures
(is reset when loading the
factory settings)
Number of implemented span
calibration procedures (is
reset when loading the factory
settings)
Maximum belt load that has
occurred
Current deviation from
original zero (when loaded)
Current deviation from
original zero (in % of nominal
load)
3xLONG
Type
L
Rw
USHORT
2
r
USHORT
2
r
USHORT
2
r
USHORT
2
r
ULONG
4
r
ULONG
4
r
ULONG
4
r
FLOAT
4
r
LONG
4
r
FLOAT
4
r
FLOAT
4
r
FLOAT
4
r
LONG
4
r
LONG
4
r
LONG
4
r
LONG
12
Default
Min.
Max.
38
-
-
64
-
-
104
-
-
1
1
65635
0
0
0
0
0
0
0
0
0
0
0
0
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Register
4500
4501
4502
4503
4504
4506
4508
4510
4512
4514
4516
4518
4520
4522
4524
4526

Hide quick links: