Data and operating errors
(code 5000 to 8999)
6004 Command cannot be executed since
a dynamic procedure is not active
7000 Permitted number range violated
7001 Regulation code not known
7002 Specifications of string lengths not
plausible
7003 Specification of date / time not
plausible
7004 Assignment of DIs/DQs incorrect
7006 Reserved
7007 The calibration weights or calibration
digits are not plausible
7008 Zeroing parameters are not plausible 7008
7010 Scale interval / rounding
7011 Filter parameters
7013 Interface assignment for calibratable
HMI not plausible
7014 Specified time not plausible
7016 Parameter assignment of analog
output not plausible
7017 MAC address cannot be changed
7018 Error in IP mask
7019 RS485 parameter error
7020 Speed parameter or sensor
parameter not plausible
7021 Units are not plausible
SIWAREX WP241
Manual, 04/2014, A5E33713528A
Error code
Description and remedy
6004
Desired command cannot be executed since a dynamic
command is not currently being executed.
7000
The permitted number range, such as for weight values, was
violated.
7001
Regulation code for application requiring official calibration
not known.
7002
The string header in a specified string variable is not
plausible.
7003
Specifications for date and time are not plausible.
7004
An error occurred while assigning the digital inputs or digital
outputs.
7006
Reserved
7007
Specifications for calibration weights or digits in data record
DR 3 are incorrect (minimum distance, reversal of incline).
The specifications for zeroing (data record DR 3) are not
plausible.
7010
Scale interval or selection for rounding to decimal places is
not plausible.
7011
Specification of filter parameters is not plausible.
7013
The assignment of the interface to the calibratable HMI is
incorrect.
7014
Specified time value is not plausible or may be signaled in
connection with additional errors
7016
The parameters for the analog output (data record DR 7) are
not plausible.
7017
7018
The specified IP addresses (DR12) are not plausible.
7019
The specified RS485 interface parameters (DR13) are not
plausible.
7020
The speed parameter or sensor parameter in DR3 is not
plausible.
7021
The selected units are not plausible (mixing of metric and
imperial parameters).