Connecting

6.7 Connection of the analog output (1 x AQ)

6.7
Connection of the analog output (1 x AQ)
Unknown assignment of the analog outputs
The assignment of the analog output is not known at the time of connection. The analog
output can be active immediately after turning on the power supply. This may damage parts
of the system.
Do not create a connection with the analog output before you know the assignment.
The analog output is not permanently assigned to a process value in the delivery state.
Assignment of the analog output to the process value as well as its response in the event of
a fault is carried out during commissioning in data record 7.
Table 6- 5
Labeling
AQ+
AQ-
6.8

Connection of RS485 serial interface

The following devices can be connected to the serial interface:
● Operator Panels or other HMI devices with RS485 and Modbus protocol RTU
● Communication partner with Modbus protocol RTU
Table 6- 6
Labeling
EIA-485 T+
EIA-485 T-
EIA-485 D+'
EIA-485 D-'
EIA-485 D+
EIA-485 D-
If a SIWAREX WP241 module forms the termination of an RS485 network, insert wire
jumpers between the D+' and T+ terminals and between the D-' and T- terminals for
termination of the bus network.
34
CAUTION
Connection of analog output
Function
Analog output +
Analog output -
Connection of RS485 serial interface
Function
RS485 termination +
RS485 termination -
RS485 data line +' for looping through of bus signal
RS485 data line -' for looping through of bus signal
RS485 data line + for feeding in of bus signal
RS485 data line - for feeding in of bus signal
SIWAREX WP241