5.13 Main Circuit Short Check

Check No.20
Note:
Check to make sure that the voltage between (+) and (–) of the diode bridge (DB1) is approx.
0 V before checking.
 Measure the resistance between the pins of the DB1 referring to the table below.
 If the resistance is  or less than 1 k, short circuit occurs on the main circuit.
Negative (–) terminal of
tester (positive terminal
(+) for digital tester)
Positive (+) terminal of
tester (negative terminal
(–) for digital tester)
Resistance is OK.
Resistance is NG.
09/12 class
151
~ (2, 3)
+ (4)
+ (4)
~ (2, 3)
several k
~ several M
0  or
0
SiUS091133
~ (2, 3)
(1)
(1)
~ (2, 3)
several k
~ several M
0
0 or
1