Daikin FTXS30LVJU Service Manual page 380

Inverter pair ftxs-l series fdxs-l series
Hide thumbs Also See for FTXS30LVJU:
Table of Contents

Advertisement

SiUS091133
Step
10 Release the thermistor
harness from the hook
at the bottom of
electrical box.
11 Pull out the clamp of
the thermistor harness
from the hole of the
electrical box.
12 Slide the electrical box
leftward to unfasten the
hook on the right side of
the box.
13 Lift up the electrical box
and remove it.
Removal Procedure
Procedure
Hook
Hook
Outdoor Unit: RKS30/36LVJU, RXS30/36LVJU
 When reassembling, insert
the clamp into the small hole.
Fixing position for the
thermistor harness
(R16647)
Electrical box
(R16643)
(R16644)
Points
370

Hide quick links: