SiUS091133
Step
4
Disconnect the
connector for fan motor
[S70] and release the 4
clamps attached to the
electrical box.
5
Release the fan motor
lead wire.
6
Disconnect the
connectors of the front
side.
Removal Procedure
Procedure
[S70]
Fan motor lead wire
[S20]
[S90]
Outdoor Unit: RKS30/36LVJU, RXS30/36LVJU
 When reassembling, insert each
Ferrite core
clamp into the small hole.
For the ferrite
core of fan
motor
For the thermistor
ASSY harnesses
(R16918)
: When reassembling, do not use
these 2 hooks.
(R14466)
[S20]: electronic expansion valve
[S80]
[S80]: four-way valve coil
[S90]: thermistors
 Cooling only models have no
harness for [S80].
(R9622)
Points
For the ferrite core
of electronic
expansion valve coil
For the four way
valve coil harness
(R16919)
coil