Outdoor Unit: RXS15/18LVJU
5.2

Removal of Outdoor Fan / Fan Motor

Procedure
Step
1
Remove the drip proof
cover.
2
Disconnect the
connector for the fan
motor [S70].
3
Release the clamp from
the partition plate.
293
Warning
Be sure to wait for 10 minutes or more after turning off all power supplies
before disassembling work.
Procedure
Ferrite core
Partition plate
Drip proof cover
(R17049)
[S70]
(R16951)
(R16952)
SiUS091133
Points
Preparation
 Remove the top panel and the
front panel according to the
"Removal of Outer Panels".
 The ferrite core of the fan motor
lead wire has a clamp.
Removal Procedure