Outdoor Unit - Daikin FTXS30LVJU Service Manual

Inverter pair ftxs-l series fdxs-l series
Hide thumbs Also See for FTXS30LVJU:
Table of Contents

Advertisement

SiUS091133
1.2

Outdoor Unit

RXS09/12LVJU

OUTDOOR UNIT

9/32CuT
9/32CuT
MUFFLER
DISCHARGE PIPE
THERMISTOR
RXS15/18LVJU
OUTDOOR UNIT
( 12.7 )
1/2CuT
( 12.7 )
1/2CuT
Appendix
OUTDOOR TEMPERATURE
HEAT EXCHANGER
THERMISTOR
HEAT EXCHANGER
THERMISTOR
3/16CuT
1/4CuT
3/16CuT
MUFFLER
WITH
M
FILTER
PROPELLER FAN
3/8CuT
FOUR WAY
VALVE
ON : HEATING
3/8CuT
COMPRESSOR
ACCUMULATOR
5/16CuT ( 7.9 )
HEAT EXCHANGER
5/16CuT ( 7.9 )
5/16CuT ( 7.9 )
5/16CuT ( 7.9 )
5/16CuT ( 7.9 )
5/16CuT ( 7.9 )
5/16CuT ( 7.9 )
5/16CuT ( 7.9 )
HEAT
EXCHANGER
THERMISTOR
M
PROPELLER FAN
( 12.7 )
1/2CuT
FOUR WAY
( 7.9 )
VALVE
5/16CuT
ON : HEATING
MUFFLER
( 7.9 )
5/16CuT
( 7.9 )
MUFFLER
5/16CuT
DISCHARGE PIPE
THERMISTOR
COMPRESSOR
ELECTRONIC
EXPANSION
VALVE
EV
1/4CuT
MUFFLER
WITH
FILTER
MUFFLER
WITH
FILTER
LIQUID STOP
VALVE
3/8CuT
MUFFLER
MUFFLER
GAS STOP
VALVE
OUTDOOR TEMPERATURE
THERMISTOR
CAPILLARY TUBE 1
( 7.9 )
(4.0)
5/32CuT
5/16CuT
MUFFLER
CAPILLARY TUBE 2
( 7.9 )
( 4.0 )
( 6.4 )
5/16CuT
5/32CuT
1/4CuT
CAPILLARY TUBE 3
( 4.0 )
5/32CuT
CAPILLARY TUBE 4
( 4.0 )
5/32CuT
( 9.5 )
3/8CuT
MUFFLER
(12.7)
1/2CuT
Piping Diagrams
FIELD PIPING
(1/4CuT)
FIELD PIPING
(3/8CuT)
REFRIGERANT FLOW
COOLING
HEATING
WITH
REFRIGERANT FLOW
FILTER
ELECTRONIC
EXPANSION
VALVE
FILTER
RECEIVER
FIELD PIPING
( 1/4 CuT )
(6.4)
LIQUID
( 6.4 )
1/4CuT
STOP VALVE
FIELD PIPING
( 1/2 CuT )
GAS STOP VALVE
( 12.7 )
WITH SERVICE PORT
3D074282
COOLING
HEATING
UNIT=INCH ( mm )
3D074451
396

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents