Error
code
E0
E0
E0
E0
E0
E0
E
Description of error
Abnormality of solenoid power
When solenoid power of servo control p.c.b. fluctuates
± 15% or more.
Abnormality of temperature of heat sink for servo
control p.c.b.
When temperature of heat sink of servo control p.c.b.
is °C or more.
Zigzag width motor origin retrieval error
When origin sensor signal is not inputted at the time of
origin retrieval motion.
Y-feed motor origin retrieval error
When origin sensor signal is not inputted at the time of
origin retrieval motion.
Needle thread trimmer motor origin retrieval error
When origin sensor signal is not inputted at the time of
origin retrieval motion.
Presser motor origin retrieval error
When origin sensor signal is not inputted at the time of
origin retrieval motion.
Bobbin thread trimmer motor origin retrieval error
When origin sensor signal is not inputted at the time of
origin retrieval motion.
–  –
How to
Place of
recover
recovery
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.
Turn OFF the
power.