Cable clamp location

Fasten each cables connected to the DCU to the location shown below. Clamp the ar-
mor of the cable. When the armor of the cable is covered with vinyl (cable jacket), re-
move it so that the armor lies in the cable clamp.
Attach the cable band (supplied) to each cable to be connected to the DCU and record
sensor name/equipment name on each cable band.
Note: If you mislay a cable, the cable clamp may not keep the cable securely.
Clamp
Cable
location No.
1
TTYCYSLA-1Q,
TTYCSLA-1Q
2
3
TTYCSLA-4
4
TTYCSLA-1Q
5
TTYCSLA-1Q
6
TTYCSLA-1
7
TTYCSLA-1
8
DPYCY-1.5*
9
DPYC-1.5*
FR-FTPC-CY,
10
MPYC-12*
11
DPYC-1.5*
Attach the rod terminal to the signal cores. For details, see "ROD TERMINALS" on page AP-7.
1
*
:
For the MPYC-12 cable, connect to the J310 (AMS) port for the connection of the contact signal.
2
*
:
Clamp the MPYC-12 cable to the same position as the LAN cables (clamp location no. 10).
Connector No.
J203-J210 (MIC1-MIC8)
J309 (RAP)
J310 (AMS)
J301-J302 (CH1-CH2)
J201-J202 (VHF1-VHF2)
J303-J308 (CH3-CH8)
J311 (DRU POWER)
1
J312 (FLOAT DRU POWER)
J313 (SENSOR ADAPTER
1
POWER)
J11-J16 (LAN1-LAN6)
2
J21-J24 (LAN9-LAN12)
J25-J25 (LAN13-LAN14)
1
J1 (AC IN)
Signal/Unit to be connected
Microphone, Waterproof micro-
phone
Remote alarm panel
AMS (Serial)
Serial input (IEC61162-1/2)
VHF audio, 2 channels
Serial input (IEC61162-1)
Output 24VDC for the fixed DRU
Output 24VDC for the float-free
DRU
Output 24VDC for the sensor
adapter or junction box (IF-8540)
Radar, ECDIS, sensor (IEC61162-
450), sensor adapter, RMS, junc-
tion box (IF-8540)
Float-free DRU, video LAN con-
verter, junction box (IF-8530)
Fixed DRU
100-230 VAC
2. WIRING
2-3