Download Print this page

Furuno VR-7000 Installation Manual page 62

Voyage data recorder
Hide thumbs Also See for VR-7000:

Advertisement

2. WIRING
How to set NC/NO output (J2)
The POWER FAIL signal on the connector J2 can be set to NC (normally closed) out-
put or NO (normally open) output as shown in the table below.
Pin #
Signal name
1
24V_IN
2
24V_GND
3
PWR_FAIL_A
4
PWR_FAIL_COM
5
PWR_FAIL_B
How to set input specification (J4 to J9)
For connectors J4 to J7, the connections are different depending on the input specifi-
cations as shown below.
Signal
Pin #
name
1
TD1-A
2
TD1-B
3
RD1-A
4
RD1-B
5
ISOGND1
6
RD1-H
7
RD1-C
*: Set the jumpers J20/J21 to Modbus.
2-26
Connector J2
In/Out
Description
-
24 VDC
-
GND (24 VDC)
Out
Power fail output
Out
Power fail output
Out
Power fail output
Connector J4
In/Out
Description
Out
Serial CH1, out-
put IEC61162-1/
2/modbus
Out
Serial CH1, out-
put IEC61162-1/
2/modbus
In
Serial CH1, input
IEC61162-2/
modbus
In
Serial CH1, input
IEC61162-2/
modbus
-
Isolation, GND
(CH1)
In
Serial CH1, input
IEC61162-1
In
Serial CH1, input
IEC61162-1
NO
DPYC-1.5
TTYCS(LA)-1
No connection
IEC61162-2
IEC61162-1
TTYCS(LA)-4
TTYCS(LA)-4
No connection No connection
No connection TTYCS(LA)-4
NC
No connection
TTYCS(LA)-1
Modbus*
TTYCS(LA)-4

Hide quick links:

Advertisement

loading