11.1

Exchange of equipment

11.1.1 Exchange of a R1000 UDK10 against a R1000 UDK20
A R1000 UDK10 can be fully replaced to by a R1000 UDK20.
Prerequisite: The UDK20 has the same suffixes as the UDK10,
e.g.: UDK10-B-R  UDK20-B-R.
The terminal blocks are pin compatible. Cables can be re-used. The previously used sensor
PW42GS must be replaced by a sensor PW42AGS.
Controlling the unit via the PLC is identical. The response times of the UDK20 are substantially
shorter than those of the UDK10 (see chapter 2.2 "Sensor data").
It must be ensured that
the power supply is capable to supply max. 60W for a UDK20 (max. 17W for UDK10),
referred to chapter 2.5 "Technical data control unit UDK20", and
the cross-section of the supply cable is sufficiently dimensioned.