Communication with the PLC

6
Communication with the PLC
Pos: 46 /Doppelblech/Geräte/UDK20/6 Kommunikation mit der SPS/Kommunikation mit der SPS - allgemein @ 1\mod_1310553109284_501.doc @ 9483 @ @ 1
The UDK20 has 9 potential-free, galvanically insulated (opto coupled) inputs. For the 4 outputs
there are relays or opto couplers available as alternatives.
Pos: 47 /Doppelblech/Geräte/UDK20/6 Kommunikation mit der SPS/Externe E/A - Steuerung @ 1\mod_1310553282901_501.doc @ 9489 @ 2233233344333 @ 1
6.1

PLC inputs

For external control parallel PLC inputs are available. These inputs can be operated via a PLC. If
several functions are executed at the same time, then the unit issues an fault message. The
following functions are possible:
Measurement Start / Stop
System test
Menu selection
Teach-In (not active as factory adjustment)
Zero adjust (not active as factory adjustment)
6.2

PLC output signals

The following signals are available as outputs:
Signal
OUT3
OUT2
OUT1
OUT0
68
ROLAND ELECTRONIC GmbH · Otto-Maurer-Str. 17 · DE 75210 Keltern · Phone +49 (0)7236-9392-0 · Fax +49 (0)7236-9392-33
Double Sheet Detector R1000 series UDK20
Meaning
Note
0-sheet output
Standard 0 V active (selectable in system configuration)
1-sheet output
Standard 0 V active (selectable in system configuration)
2-sheet output
Standard 0 V active (selectable in system configuration)
ENABLE output
Standard 24 V active (not selectable, for safety reasons)
Manual
Opto coupler outputs
B0048991 / Rev. 1.3