Kohler MPAC 1500 Manual page 128

Hide thumbs Also See for MPAC 1500:
Table of Contents

Advertisement

Setup Screens
Set Time/Date
D
Set Time
D
Set Date
D
Set Automatic Daylight Saving Time
Set Exerciser
For each exerciser event:
D
Enable/Disable
D
Loaded/Unloaded
D
Interval
D
Repeat Rate
D
Duration
D
Start Date
D
Start time
Set Prime Power Run
D
Enable/Disable
D
Duration at Source1 DD:HH:MM
D
Duration at Source2 DD:HH:MM
D
Sequence Start/Stop
Set S1 Time Delays (Set S2 Time Delays)
D
Engine Start
d
External Battery? Y or N
d
Time Delay min:sec
D
Engine Cooldown Time Delay min:sec
D
Xfr Preferred>Standby (Standby>Preferred)
D
Xfr Off > Standby (Off >Preferred)
(programmed--transition only)
D
Fail to Acquire Preferred (Standby)
d
Enable/Disable
d
Time Delay min:sec
D
Load Control
d
Mode: None/Time/Current
d
Loads to Control (1--9)
D
Time-Based Control (for each connected load)
d
Load Disconnect N>E (E>N) Time Delay min:sec
d
Load Add E>N (N>E) Time Delay min:sec
D
Current-Based Control
d
Load Disc N>E (E>N) time delay min:sec
d
For each connected load:
d
Load Add Source1 (Source2) Time Delay min:sec
d
Load Add Source1 (Source2) Priority
d
Load Remove Source1 (Source2) Time Delay min:sec
d
Load RemoveSource1 (Source2) Priority
d
Load Control Enable/Diable
d
Set Hi current Level, Load Remove Source1 (Source2)
d
Set Lo Current Level, Load Add Source1 (Source2)
128 Appendix
Set Source
D
Phase Rotation ABC/BAC/Disabled
D
Set In-Phase Monitor
d
Enable/Disable
d
Angle
d
In-Phase Transfer Fail Time Delay
d
Enable/Disable
d
Time Delay min:sec
D
Set Synchronization
d
Voltage Differential
d
Frequency Differential
d
Angle Differential
d
Fail to Sync
d
Enable/Disable
d
Time Delay min:sec
D
Set Preferred Source Normal/Emergency
D
Set Normal (Emergency) Source:
d
Number of Phases
d
Voltage
d
Frequency
d
Under Voltage Pickup
d
Under Voltage Dropout
d
Over Voltage Pickup
d
Over Voltage dropout
d
Voltage Debounce Time
d
Voltage Unbalance Enable/Disable
d
Voltage Unbalance Pickup
d
Voltage Unbalance Dropout
d
Under Frequency Pickup
d
Under Frequency Dropout
d
Over Frequency Pickup
d
Over Frequency Dropout
d
Frequency Debounce time
Set Input/Output
D
Set Main Board I/O
d
Set Input Functions *
d
Set Output Functions [
D
Set Auxiliary I/O (Modules)
d
Set Input Functions *
d
Set Output Functions [
* See Section 5.12.3, Input Functions
[ See Section 5.12.4, Output Fundtions.
Set Common Alarms
D
Alarm Group 1 or 2
D
Modify Alarm
d
Common (Yes/No)
d
Audible (Yes/No)
D
Remove All Alarms Yes/No
TP-6714
4/10

Advertisement

Table of Contents
loading

Table of Contents