Kohler MPAC 1500 Manual page 117

Hide thumbs Also See for MPAC 1500:
Table of Contents

Advertisement

Switch Position
Operation, Automatic Switches
D Automatically transfers to the standby source, when available, if the preferred source is lost
AUTO
D Transfers back to the preferred source when it becomes available
D Automatically transfers to an available source if the
MANUAL
connected source is lost
D Does not automatically transfer back to preferred
when both sources are available
D Can use to transfer when the switch is in the MANUAL
TRANSFER
(momentary switch
position and both sources are available
position)
D Initiates transfer sequence to the other source, if
available, including all programmed time delays
D Operates pre- and post-transfer load control time
delays if both sources are available
Figure 8-26
Supervised Transfer Control Switch Operation
TP-6714
4/10
Operation, Non-Automatic Switches
D Enables the Not-in-Auto indicator
D Transfers only when the switch is manually moved to
the TRANSFER position:
d Does not automatically transfer to an available
source when the connected source is lost
d Does not automatically transfer back to preferred
when both sources are available
D Must use for all transfers when the switch is in the
MANUAL position
D Initiates transfer sequence to the other source, if
available, including all programmed time delays
D Operates pre- and post-transfer load control time
delays if both sources are available
Section 8 Accessories