Kohler MPAC 1500 Manual page 126

Hide thumbs Also See for MPAC 1500:
Table of Contents

Advertisement

View Exerciser Setup
D
Exercise Event Number
D
Enabled/Disabled
D
Exercise Run Time
D
Start Date
D
Start Time
D
Weekly/Biweekly
D
Loaded/Unloaded
View System Setup
D
Open/Programmed/Closed Transition
D
Source Type: Util/Gen, Gen/Gen, Util/Util or Util/Gen/Gen
D
Service Entrance: Yes/No
D
In--Phase Monitor Enabled/Disabled
D
Commit/No Commit to Transfer
D
# I/O Modules Installed
D
Rated Current
D
3 Src Engine Start Mode Mode1/Mode2
D
Remote Test Loading Loaded/Unloaded
D
Peak Shave Delay Enabled/Disabled
View Source Setup
D
ABC/BAC Rotation (3-phase only)
D
System Voltage, Normal/Emergency
D
Frequency (Hz), Source N and E
D
Normal Under Voltage PU% and DO%
d
Normal Over Voltage PU% and DO%
d
Debounce Time, Seconds
D
Normal Under Frequency PU% and DO%
d
Debounce Time
D
Normal Voltage Unbalance Enable/Disable
d
Normal Voltage Unbalance PU% and DO%
D
Emergency Under Voltage PU% and DO%
d
Emergency Over Voltage PU% and DO%
d
Debounce Time
D
Emergency Under Frequency PU% and DO%
d
Emergency Over Frequency PU% and DO%
d
Debounce Time
D
Emergency Voltage Unbalance Enable/Disable
d
Emergency Voltage Unbalance PU% and DO%
D
In-Phase Monitor
d
Enabled/Disabled
d
Angle, degrees
D
In-Phase Transfer Fail
d
Enabled/Disabled
d
Time Delay min:sec
126 Appendix
View Source Setup, Continued
D
Synchronization (for closed-transition)
d
Voltage Differential
d
Frequency Differential
d
Angle differential
D
Fail toSync
d
Enabled/Disabled
d
Time Delay min:sec
View Time Delays, Source S1 and Source S2
D
Engine Start (gen set only)
D
Engine Cooldown
D
Xfr Preferred>Standby (Standby>Preferred)
D
Xfr Off > Standby (Off >Preferred)
(programmed--transition only)
D
Fail to Acquire Preferred (Standby)
D
Load Control
d
Mode: None/Time/Current
d
Loads to Control (1--9)
D
Time-Based Control
d
Load Disconnect N>E (E>N) Time Delay min:sec
d
Load Add E>N (N>E) Time Delay min:sec
D
Current-Based Control
d
Load Disc N>E (E>N) time delay min:sec
d
Load control Source1 (Source2) Enabled/Disabled
d
Load Add Source1 (Source2) Time Delay min:sec
d
Load Add Source1 (Source2) Priority
d
Load Remove Source1 (Source2) Time Delay min:sec
d
Load RemoveSource1 (Source2) Priority
d
Amps Level Remove Source1 (Source2)
d
Amps Level Add Source1 (Source2)
View Inputs/Outputs
D
Main Board I/O
d
Input Function Descriptions (2)
d
Output Function Descriptions (2)
D
Auxiliary Inputs/ Outputs
d
Aux I/O Module
d
Module Type and Address
d
Module Status
d
Input Function Descriptions
d
Output Function Descriptions
View Common Alarms
D
Alarm Group (1 and 2)
D
Alarm Description
D
Audible (Yes or No)
D
Common (Yes or No)
TP-6714
4/10

Advertisement

Table of Contents
loading

Table of Contents