Cautions In Servicing; Connectors; Couplers; Clamps - Suzuki DR 125 Service Manual

Table of Contents

Advertisement

6-2 ELECTRICAL SYSTEM

CAUTIONS IN SERVICING

CONNECTORS

• When disconnecting a connector, be sure to hold the termi-
nals; do not pull the lead wires.
• When connecting a connector, push it in so it is firmly
attached.
• Inspect the connector for corrosion, contamination and any
breakage in the cover.
• Avoid applying grease or other similar material to connector/
coupler terminals to prevent electric trouble.

COUPLERS

• With a lock-type coupler, be sure to release the lock before
disconnecting it. When connecting a coupler, push it in until
the lock clicks shut.
• When disconnecting a coupler, be sure to hold the coupler; do
not pull the lead wires.
• Inspect each terminal on the coupler for looseness or bends.
• Inspect each terminal for corrosion and contamination.

CLAMPS

• Refer to the "WIRE CABLE AND HOSE ROUTING" section
for proper clamping procedures. (7-10 and -11)
• Bend the clamp properly, as shown in the illustration.
• When clamping the wire harness, do not allow it to hang
down.
• Do not use wire or any substitutes for the band-type clamp.

SEMI-CONDUCTOR EQUIPPED PARTS

• Do not drop any part that contains a semi-conductor (e.g.,
CDI unit).
• When inspecting the part, follow the inspection instructions
carefully. Neglecting proper procedures may cause this part
to be damaged.

WIRING PROCEDURE

• Properly route the wire harness according to the "WIRE
ROUTING" section. (7-10)
INCORRECT