s c n S e t S c a n I n f o
Description
Saves the scanner's configuration values the application set in
the SCANINFO data structure. See "SCANINFO" in Chapter 5
for a description of this data structure.
To configure the scanner, the application:
1. Enables the scanner with scnOpenScanner or
scnOpenScannerShared.
2. Calls scnGetScanInfo.
3. Sets the values in the SCANINFO data structure.
4. Calls scnSetScanInfo.
Syntax
short far scnSetScanInfo(LPSCANINFO lprScanInfo);
Parameters
lprScanInfo
Return Values
0
-9
4-90
Programmer's Manual
This function is invalid with LMSSCEN.LIB.
When the application disables the scanner,
the configuration values go back to the
A pointer to a SCANINFO data structure.
Successful.
The scanner is disabled.
defaults.