O p t i o n 5 0 ( B a r C o d e D e n s i t y )
You can apply this option to bar code fields when you want to
create custom densities. When you apply this option, it overrides
the density value in the bar code field. When using this option,
set the density parameter in your bar code field to the default
value. You can only use this option once for each bar code field.
This option overrides the density selected in the bar code field.
Bar codes produced using Option 50 may not be scannable.
Code 39, density 12, produces a one-dot narrow bar. This density
is intended for special U.S.P.S. ACT-tag applications only.
Synthetic supplies are recommended to produce scannable bar
codes.
The additional character gap, narrow space, and wide space
parameters are valid only with Code 39 and Codabar. If these
parameters are specified for any other bar codes, they will be
ignored by the printer. Do not use Option 50 with fixed density
bar codes.
Syntax
R1. R
R2. 50
R3. narrow
R4. wide
R5. gap
R6. nar_space
R7. wide_space
Example
4-12 Defining Field Options
R,50,narrow,wide,gap,nar_space,
wide_space p
Option Header.
Option 50.
Dot width of the narrow element. Range: 1-99.
Dot width of the wide element. Range: 1-99.
Additional dot space between characters. Enter a value of 1
to 99. (Code 39 and Codabar only.)
Additional dot width of the narrow bar code space. (Code 39
and Codabar only). Range: 1- 99.
Additional dot width of the wide bar code space. (Code 39
and Codabar only). Range: 1- 99.
R,50,4,8,4,4,8 p