Power Connection Compliance; Assembling And Connecting The Dc Power Cable To The Router - Cisco ASR 901S Series Installation Manual

Hide thumbs Also See for ASR 901S Series:
Table of Contents

Advertisement

Power Connection Compliance

Procedure
Step 1
Verify that the cover seal is clean and that all cables are tucked back into the chassis.
Step 2
To close the cover, use the special screw driver to evenly tighten all twelve captive bolts in the order as shown
in
Opening the Router Cover, on page
Step 3
Evenly tighten the bolts again, this time using 1152 to1344 in oz (8.13 to 9.49 Nm) of torque.

Power Connection Compliance

Warning
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Statement 1003
Use copper conductors only. Statement 1025
Warning

Assembling and Connecting the DC Power Cable to the Router

Materials Required
To assemble and connect a DC power cable, you need to supply these tools and material:
• 3 core outdoor-rated DC power cable (minimum 16 AWG) with outside cable diameter of 0.20 to 0.45
Cisco ASR 901S Series Aggregation Services Router Hardware Installation Guide
52
inch (0.51 to 1.14 cm).
48.
Installing the Router