Configuring The Nqa Statistics Collection Function - HP 5820X Switch Configuration Manual

Network management and monitoring
Hide thumbs Also See for 5820X Switch:
Table of Contents

Advertisement

To do...
Configure a reaction entry for
monitoring the one-way delay
(only supported in UDP jitter
and voice tests)
Configure a reaction entry for
monitoring the ICPIF value
(only supported in voice tests)
Configure a reaction entry for
monitoring the MOS value
(only supported in voice tests)
NOTE:
NQA DNS tests do not support the action of sending trap messages. The action to be triggered in
DNS tests can only be the default one, none.
Only the test-complete keyword is supported for the reaction trap command in a voice test.

Configuring the NQA statistics collection function

NQA groups tests completed in a time period for a test group, and calculates the test result statistics. The
statistics form a statistics group. To view information about the statistics groups, use the display nqa
statistics command. To set the interval for collecting statistics, use the statistics interval command.
When the number of statistics groups kept reaches the upper limit and a new statistics group is to be
saved, the earliest statistics group is deleted. To set the maximum number of statistics groups that can be
kept, use the statistics max-group command.
A statistics group is formed after the last test is completed within the specified interval. When its hold time
expires, the statistics group is deleted. To set the hold time of statistics groups for a test group, use the
statistics hold-time command.
To configure the NQA statistics collection function:
To do...
1.
Enter system view.
2.
Enter NQA test group view.
3.
Enter test type view of the test
group.
4.
Configure the interval for
collecting the statistics of test
results.
5.
Configure the maximum
number of statistics groups
that can be kept.
Use the command...
reaction item-number checked-element { owd-ds
| owd-sd } threshold-value upper-threshold
lower-threshold
reaction item-number checked-element icpif
threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
reaction item-number checked-element mos
threshold-value upper-threshold lower-threshold
[ action-type { none | trap-only } ]
Use the command...
system-view
nqa entry admin-name operation-
tag
type { dlsw | dns | ftp | http |
icmp-echo | snmp | tcp | udp-
echo | udp-jitter | voice }
statistics interval interval
statistics max-group number
29
Remarks
Remarks
Optional.
60 minutes by default.
Optional.
2 by default.
To disable collecting NQA
statistics, set the maximum number
to 0.

Hide quick links: