Configuring UDP echo tests

UDP echo tests of an NQA test group tests the connectivity and round-trip time of a UDP packet from the
client to the specified UDP port on the NQA server.
Configuration prerequisites
UDP echo tests require cooperation between the NQA server and the NQA client. Before you start UDP
echo tests, configure a UDP listening service on the NQA server. For more information about the UDP
listening service configuration, see
Configuring UDP echo tests
To configure UDP echo tests:
To do...
1.
Enter system view.
2.
Enter NQA test group view.
3.
Configure the test type as UDP
echo and enter test type view.
4.
Configure the destination
address of UDP packets.
5.
Configure the destination port
of UDP packets.
Use the command...
source ip ip-address
See
"Configuring optional
parameters for an NQA test
group"
"Configuring the NQA
Use the command...
system-view
nqa entry admin-name operation-
tag
type udp-echo
destination ip ip-address
destination port port-number
23
Remarks
Optional.
By default, no source IP address is
specified.
The source IP address must be the
IP address of a local interface.
The local interface must be up;
otherwise, no probe packets can
be sent out.
Optional.
server."
Remarks
Required.
Required.
By default, no destination IP
address is configured.
The destination address must be
the same as the IP address of the
listening service configured on the
NQA server.
Required.
By default, no destination port
number is configured.
The destination port number must
be the same as that of the
listening service on the NQA
server.