Configuring attributes of IPv6 NetStream data
export
Configuring IPv6 NetStream export format
The IPv6 NetStream export format configures to export IPv6 NetStream data in version 9 formats, and the
data fields can be expanded to contain more information, such as the following information:
Statistics about source AS, destination AS, and peer ASs in version 9 format.
•
Statistics about BGP next hop in version 9 format.
•
To configure the IPv6 NetStream export format:
To do...
1.
Enter system view.
2.
Configure the version for
IPv6 NetStream export
format, and specify whether
to record AS and BGP next
hop information.
Configuring refresh rate for IPv6 NetStream version 9 templates
Version 9 is template-based and supports user-defined formats, so the NetStream device needs to resend
the new template to the NetStream server for an update. If the version 9 format is changed on the
NetStream device and not updated on the NetStream server, the server is unable to associate the
received statistics with its proper fields. To avoid such situation, configure the refresh frequency and rate
for version 9 templates so that the NetStream server can refresh the templates on time.
To configure the refresh rate for IPv6 NetStream version 9 templates:
To do...
1.
Enter system view.
2.
Configure the refresh frequency for
NetStream version 9 templates.
3.
Configure the refresh interval for
NetStream version 9 templates.
Use the command...
system-view
ipv6 netstream export version 9 [ origin-
as | peer-as ] [ bgp-nexthop ]
Use the command...
system-view
ipv6 netstream export v9-
template refresh-rate packet
packets
ipv6 netstream export v9-
template refresh-rate time
minutes
217
Remarks
—
Optional.
By default, version 9 format
is used to export IPv6
NetStream traditional data,
IPv6 NetStream aggregation
data, and MPLS flow data
with IPv6 fields; the peer AS
numbers are recorded; the
BGP next hop is not
recorded.
Remarks
—
Optional.
By default, the version 9
templates are sent every 20
packets.
Optional.
By default, the version 9
templates are sent every 30
minutes.