External Process; External I/O Initialization - Delta E Series Software Instructions

Recipe setting
Table of Contents

Advertisement

Recipe Setting Software Instruction
3.2

External Process

3.2.1

External I/O initialization

1.
Switch the control selector button to [External Control]
2.
Trigger the [Safety Signal]. [X3]→ON
3.
Please refer to the table below to select a recipe with binary values
Recipe number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
4.
Trigger the [On] signal, and the machine will perform [Initialize] and [Start]. [X0]→Continuous ON
5.
After the initialization of the machine is completed, the signal of [Ready] is output.
[Y0]→Continuously ON
X7
X6
Bit 3
Bit 2
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
20
X5
X4
Bit 1
Bit 0
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON