Selection Of Operation Mode; Chapter 6 Control Mode Of Operation - Delta ASDA-A2 User Manual

Delta high resolution ac servo drive for network communication applications
Hide thumbs Also See for ASDA-A2:
Table of Contents

Advertisement

6.1 Selection of Operation Mode

Three basic operation modes are provided in this servo drive, position, speed and torque. Users
can use single mode (only in one-mode control) and dual mode to control. The following table lists
all operation mode and description.
Mode Name
Position mode
(Terminal input)
Position mode
(Register input)
Speed Mode
Single
Mode
Speed mode
(No analog input)
Torque mode
Torque mode
(No analog input)
Revision February, 2017
Chapter 6 Control Mode of
Short
Setting
Name
Code
PT
00
PR
01
S
02
Sz
04
T
03
Tz
05
Description
The servo drive receives position command and
commands the motor to the target position. The
position command is input via terminal block and
receives pulse signal.
The servo drive receives position command and
commands the motor to the target position. The
position command is issued by register (64 sets
of register in total) and uses DI signal to select
the register.
The servo drive receives speed command and
commands the motor to the target speed. The
speed command can be issued by register (3
sets of registers in total) or the external analog
voltage (-10V ~ +10V). DI signal is used to
select the command source.
The servo drive receives speed command and
commands the motor to the target speed. The
speed command is issued by register (3 sets of
registers in total) and cannot be issued by the
external terminal block. DI signal is used to
select the command source.
The servo drive receives torque command and
commands the motor to the target torque. The
torque command can be issued by register (3
sets of registers in total) or the external analog
voltage (-10V ~ +10V). DI signal is used to
select the command source.
The servo drive receives torque command and
commands the motor to the target torque. The
torque command can be issued by register (3
sets of registers in total) and cannot be issued
by the external terminal block. DI signal is used
to select the command source.
Operation