128 en | Keypad Installer menu
HTTP Port Number
IPv4 Server Address
IPv6 Server Address
Module Hostname
DHCP/AutoIP Enable
B91x/B92x keypads configuration of DHCP/AutoIP Enable
1.
2.
3.
4.
5.
6.
B93x/B94x keypads configuration of DHCP/AutoIP Enable
1.
2.
3.
4.
5.
UPnP Enable
B91x/B92x keypads configuration of UPnP Enable
1.
2.
3.
4.
5.
6.
B93x/B94x keypads configuration of UPnP Enable
1.
2.
3.
4.
5.
2016.06 | 08 | F.01U.303.996
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
Press [ENTER] to edit the DHCP/AutoIP Enable configuration for the module.
Use [PREV] or [NEXT] to toggle between Yes and No.
Press [ENTER] while viewing the desired option to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [1] DHCP. The keypad shows the DHCP/AutoIP current
configuration.
Press [Yes] or [No] – whichever is available – to change the programming.
Press [Save] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [2] UPnP. The keypad shows the UPnP current configuration.
Press [ENTER] to edit the UPnP Enable configuration for the module.
Use [PREV] or [NEXT] to toggle between Yes and No.
Press [ENTER] while viewing the desired option to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Enter the installer passcode, and then open the [1] Installer menu.
Go to [1] Program > [2] Network > [1] Ethernet > (choose the bus module or on-board) >
[1] Module Parameters > [2] UPnP. The keypad shows the UPnP current configuration.
Press [Yes] or [No] – whichever is available – to change the programming.
Press [Save] to save the programming.
When the keypad shows Parameter Saved, escape from the menu.
Installation and System Reference Guide
80
_______________________________
0.0.0.0
_______________________________
0.0.0.0
_______________________________
Blank
_______________________________