Normally, modulation and other parameters
affected by the movement of controllers (except for
main volume) are reset when a program change is
executed. You can prevent the resetting of these
parameters by setting the controller hold function to
"on". When this setting is made, all parameter
values are maintained regardless of their controller
assignments. For example, if pitch modulation is
applied to one voice using MODULATION 1, the same
amount of pitch modulation will be applied to the
next voice that is selected so long as pitch
modulation is enabled for that voice. (Note that
SYSTEM UTILITY
Summary: The "Are you sure?" message that ap-
pears when you store, recall, or initialize data
can be turned on/off.
Procedure:
From: system utility job directory (JUMP #800)
Select: 04:Edit Confirm
Specify: whether or not the confirm message will
appear
SYSTEM UTILITY
Summary: Edit the two-line message that is briefly
displayed when the SY99 power is turned on.
Procedure:
From: system utility job directory (JUMP #800)
Select: 05:Greeting Message
Specify: the greeting message
pitch modulation need not be assigned to
MODULATION 1 — or any other controller, for that
matter - for the controller hold function to take
effect.)
eters affected by the movement of controllers will be
reset when the SY99's mode is changed from Multi
to Voice mode (or vice versa), or by the execution of
a program change in Multi mode, even if the
controller hold function is turned on.

4. Edit confirm

0 Edit Confirm (on, off): When this is on you will
(JUMP #804)
Remarks: Until you are familiar with the SY99 we
5. Greeting message
(JUMP #805)
Remarks: Methods of entering character data are
Main volume, modulation, and all other param-
be asked "Are you sure?" whenever an opera-
tion that erases or replaces data is about to be
performed. When this is off the operation will be
executed without asking for confirmation.
recommend that you leave this on.
Enter the two-line x 20 character greeting
message.
To clear the currently entered message press Fl
(Clr). (If you clear the greeting message, the
greeting message box will not appear when the
SY99's power is turned on.) To switch to upper-
case characters press F2 (Uppr). To switch to
lower-case characters press F3 (Lowr).
explained in How to enter data of Introducing the
SY99.