● Note the following points when setting port numbers.
Connection status
Connected device
E71
Connected device
Connected device
E71
Connected device
E71
Connected device
E71
Connected device
E71
Connected device
E71
Connected device
● Consult with the network administrator for setting the port numbers of the E71 and the connected device and the IP
address of the connected device.
Description
When connecting multiple connected devices, set multiple
own station port numbers.
When connecting multiple connected devices, set a single
own station port number. (However, connections need to be
opened by the number of connections.)
This setting cannot be configured when the own station is
Unpassive.
When connecting multiple ports on a connected device, set
multiple port numbers of the E71.
When connecting multiple ports on a connected device, set
a single port number of the E71. (However, connections
need to be opened by the number of connections.)
This setting cannot be configured when the own station is
Unpassive.
When connecting the same port on a connected device, set
multiple port numbers of the E71. (However, connections
need to be opened by the number of connections.)
Multiple ports can be set for the same port on a connected
device and on the E71 only when paring open has been set.
CHAPTER 7 COMMUNICATION PROCEDURE
: Can be set, ×: Cannot be set
Communication
protocol
TCP/IP
UDP/IP
×
7
×
87