6.2.2

Wiring with the QJ71E71-B5

The following describes connection and disconnection of the AUI cable and connection of the external power supply
terminal.
(1) Connecting the cable
1.
Slide the retainer in the orientation A and insert the AUI cable connector all the way in.
2.
Slide the retainer in the orientation B and make sure that the AUI cable is securely locked into
place.
3.
Connect the external power supply terminal (DC power supply for a transceiver).
Strip the cable jacket by 13mm.
4.
Loosen the terminal screw and insert the cable into the terminal.
5.
Tighten the terminal screw within the torque range listed in Section 6.1 (2).
*1
If the wire strip length is too long, the conductive part is exposed and it may increase the risk of electric shock or short-
circuit between the adjacent terminals. If the wire strip length is too short, it may result in poor contact.
Retainer
A
B
External power supply terminal
(DC power supply for a transceiver)
*1
The applicable cable size is 0.13mm
13mm
CHAPTER 6 INSTALLATION AND WIRING