Mitsubishi Electric QJ71E71-100 User Manual page 334

Q corresponding ethernet interface module
Table of Contents

Advertisement

Error
code
C13C
System error (The OS detected an error.)
H
C140
The POP3 server could not be opened.
H
Communications cannot be performed with the POP3
C141
H
server. (Error response)
Communications cannot be performed with the POP3
C142
H
server. (Abort)
Communications cannot be performed with the POP3
C143
H
server. (Reset response)
A response from the POP3 server could not be
C144
H
received.
C145
Forcefully disconnected from the POP3 server
H
C146
The POP3 server could not be closed.
H
C147
Closing the POP3 server gave an error response.
H
C150
POP3 server verification error
H
The Ethernet module's mail address (e-mail setting
C151
parameter) is different from the account name in the
H
mailbox on the server side.
The Ethernet module's password (e-mail setting
C152
parameter) is different from the password on the server
H
side.
An error has occurred in acquisition of the received mail
C153
list. (The list of the mail that arrived at the POP3 server
H
failed to be acquired.)
An error has occurred upon receiving a mail. (An e-mail
C154
H
cannot be read from the POP3 server.)
A response was received from the DNS server after
C160
H
timeout.
C161
A response from the DNS server could not be received.
H
C162
System error (The OS detected an error.)
H
332
Error description
• Follow the procedure below.
(1)
Check if each module is properly mounted on the base unit.
(2)
Check if the operating environment of the Ethernet module
conforms to the general specifications of the CPU module.
(3)
Check if the power capacity is sufficient.
(4)
Check if the hardware is normal according to the manual for
each module.
If the actions above do not solve the problem, please consult your
local Mitsubishi representative.
• Check that the port number of the POP3 server is 110. (The port
number of the Ethernet module is fixed to 110.)
• Check if communications with the POP3 server can be performed
using the PING command.
• Check if the POP3 server is busy.
• Check if the POP3 server is busy.
• Check if the POP3 server is busy.
• Check for an error in the POP3 server.
• Check if the network is heavily loaded.
• Check for an error in the POP3 server.
• Check for an error in the POP3 server.
• Check if the network is heavily loaded.
• Check for an error in the POP3 server.
• Check the status of the POP3 server.
• Check the account name of the mailbox on the server side and
correct the account of the mailbox set in the Ethernet module.
• Check the password on the server side and correct the password
of the Ethernet module.
• Reset the server inquiry time to the default value and restart the
CPU module of the own station.
• Check that the e-mail is not compressed or encrypted.
• Check if the e-mail specifications, such as the encoding/decoding
style and file format, on the sending side are the same as those for
the Ethernet module.
• Check if the network is heavily loaded.
• Check the status of the DNS server.
• Check if the network is heavily loaded.
• Check the status of the DNS server.
• Follow the procedure below.
(1)
Check if each module is properly mounted on the base unit.
(2)
Check if the operating environment of the Ethernet module
conforms to the general specifications of the CPU module.
(3)
Check if the power capacity is sufficient.
(4)
Check if the hardware is normal according to the manual for
each module.
If the actions above do not solve the problem, please consult your
local Mitsubishi representative.
Action

Advertisement

Table of Contents
loading

This manual is also suitable for:

Qj71e71-b5Qj71e71-b2

Table of Contents