Requirement
You are in the Interface Configuration mode of the WLAN interface.
The command prompt is as follows:
cli (config-if-wlan-0-X)#
Syntax
Call up the command with the following parameters:
wlan mode { show-modes | [2.4 | 5] <mode>}
The parameters have the following meaning:
Parameters Description
show-
modes
2.4
5
mode
Depending on the current configuration, some settings are not possible. In this case, a
message to this effect is displayed.
SCALANCE W760/W720 to IEEE 802.11n Command Line Interface
Configuration Manual, 11/2014, C79000-G8976-C351-03
Lists the transmission standards.
Optional. You can use the parameter in
conjunction with "auto" and "n". This
only takes into account the transmis-
sion standard for 2.4 GHz.
Use the parameter if the client operates
in dual-frequency mode.
Optional. You can use the parameter in
conjunction with "auto" and "n". This
only takes into account the transmis-
sion standard for 5 GHz.
Use the parameter if the client operates
in dual-frequency mode.
Value corresponding to a specific
transmission standard.
Values or range of values
--
--
--
auto
The transmission standard is detected
automatically.
a
IEEE 802.11a (5 GHz)
g
IEEE 802.11g (2.4 GHz)
Is downwards compatible with IEEE
802.11b
n
IEEE 802.11n (2.4 GHz + 5 GHz)
Is downwards compatible with IEEE
802.11a and IEEE 802.11g
n-only
IEEE 802.11n (2.4 GHz + 5 GHz)
Is not downwards compatible with IEEE
802.11a and IEEE 802.11g