2.
Select a duration to display the screen saver before the output sync is disabled.
Select the
Disable Sync After
a set duration without an active input. When selected, the
field becomes available.
In the
field, enter a value in the field or click the
Duration
specify a duration to wait before disabling output sync during inactivity. The default
is to never disable the output sync.
HDCP Notification panel
HDCP notification indicates when HDCP content restrictions prevent a video signal from
passing. Select one of the following radio buttons (see
— Displays a black or muted screen when an encrypted source is sent to a
Black
display that is not HDCP-compliant.
— Displays a green screen when an encrypted source is displayed on a sink that
Green
is not HDCP-compliant (default).
OSD Input Information panel
1.
To display input information on the OSD after input selection, select the
Screen Display (OSD)
2.
In the
Duration On Screen
set a duration the information is displayed on the OSD menu. The default value is 3.
Auto Switch panel
Auto switch mode automatically switches inputs based on detected input signals.
1.
Select the
Enable Auto Switch
2.
Click the radio button of the desired type of auto switch mode from the following:
Priority to the highest active input number
the input to the highest numbered active input.
Priority to the lowest active input number
input to the lowest numbered active input.
Mute Video and Sync panel
Click the
Mute Video and Sync
the HDMI outputs.
HDCP Mode panel
When enabled, the HDCP Mode can be set to either follow the current input, with or without
DVI trials, or always encrypt the output, with or without DVI trials (
Select one of the following radio buttons:
— Encrypts the output only when required by the selected input source.
Follow Input
Always Encrypt Output
status of the selected input source.
Follow Input (with continuous DVI trials)
required by the selected input source. Use this setting when DVI sink devices initially
pass HDCP encrypted content, but intermittently display a green HDCP notification
screen after a power cycle or resuming from sleep mode.
Always Encrypt Output (with continuous DVI trials)
the output regardless of the HDCP status of the selected input source. Use this setting
when DVI sink devices initially pass HDCP encrypted content, but intermittently display
a green HDCP notification screen after a power cycle or resuming from sleep mode.
IN1606 and IN1608 Series Scaling Presentation Switcher • Internal Web Pages
check box to disable the scaler output sync after
figure
check box (
).
3
field, enter a value or click the
check box (
) to enable auto switch mode.
4
button (
) to mute the active video and disable sync on
5
— Always encrypts the output, regardless of the HDCP
— Encrypts the output only when
Duration On Screen
and
arrows to
Up
Down
80,
on page 113):
2
Enable On
or
arrow button to
Up
Down
— Automatically switches
— Automatically switches the
).
6
— Always encrypts
114

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

In1608 series

Table of Contents