Extension No Answer Redirection Time - Panasonic KX-TDA100 Pc Programming Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

Feature Guide References
None

Extension No Answer Redirection Time

Specifies the length of time that a call queues at an extension before it is redirected to the next
member extension of the incoming call distribution group, in UCD or Priority Hunting distribution
method.
Value Range
None, 10 × n (n=1–15) s
Maintenance Console Location
2.10.13 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Guide References
1.2.2.2 Group Call Distribution
1.2.2.4 Queuing Feature
No. of Unanswered Calls for Automatic Log-out
Specifies the number of consecutive unanswered calls before a member extension is automatically
logged out from the incoming call distribution group.
Value Range
None, 1–15
Maintenance Console Location
2.10.13 [3-5-1] Incoming Call Distribution Group—Group Settings
Programming Manual References
None
Feature Guide References
1.2.2.7 Log-in/Log-out
Maximum No. of Busy Extension
Specifies the number of extensions that can accept calls simultaneously in the incoming call
distribution group.
Value Range
Max: Call arrives at an idle extension.
1–32 : Call will not arrive at an idle extension when the number of busy extensions exceeds the
assigned number.
2.10 [3] Group