2.8.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-
TDA200/KX-TDA600 only)
The properties for the E & M card can be specified.
Interface
Selects E & M signal type.
Value Range
Continuous, Pulsed with Answer, Pulsed without Answer, Continuous No Answer
Maintenance Console Location
2.8.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
First Dial Timer (TIE)
Specifies the minimum time that the PBX waits after seizing a DDI/DID or TIE line, before sending the
dialled digits to the telephone company or to another PBX. This allows the telephone company or the
other PBX to have enough time to accept the dialled digits correctly.
Value Range
32 × n (n=1–255) ms
Maintenance Console Location
2.8.27 [1-1] Slot—Card Property - EM type (KX-TDA100/KX-TDA200/KX-TDA600 only)
Programming Manual References
None
Feature Guide References
None
Answer Detection Timer
Specifies the length of time required by the PBX to recognise the answer signal. This allows the
telephone company to have enough time to accept the dialled digits correctly.
Value Range
32 × n (n=1–255) ms
2.8 [1] Configuration
PC Programming Manual
273