1-1] Slot-Card Property - Ip Extension-Common Settings - Panasonic KX-TDA100 Pc Programming Manual

Hybrid ip-pbx
Hide thumbs Also See for KX-TDA100:
Table of Contents

Advertisement

2.8.37 [1-1] Slot—Card Property - IP Extension—Common
Settings
IP network data transmission settings can be programmed. To activate any changes made to settings
on this screen, it is necessary to set all installed IP-EXT cards to OUS, then back to INS.
Gateway Address
Specifies the default gateway address of the IP network.
Value Range
0.0.0.0–223.255.255.255
Maintenance Console Location
2.8.37 [1-1] Slot—Card Property - IP Extension—Common Settings
Programming Manual References
2.8.36 [1-1] Slot—Card Property - IP Extension—Gateway Address [Common Settings]
Feature Guide References
1.31.1 IP Proprietary Telephone (IP-PT)
Voice (RTP) UDP Port No. (Server)
Specifies the UDP port used by the IP-EXT card to transmit and receive RTP (Realtime Transfer
Protocol) data. This must be changed if another network application is using the same port.
For voice communications, an IP-EXT16 card uses 64 and an IP-EXT4 card uses 16 contiguous UDP
ports, starting from the port number specified here.
Value Range
1024–65472
Maintenance Console Location
2.8.37 [1-1] Slot—Card Property - IP Extension—Common Settings
Programming Manual References
None
Feature Guide References
1.31.1 IP Proprietary Telephone (IP-PT)
Voice (RTP) UDP Port No. (IP-PT)
Specifies the UDP port used to transmit and receive RTP (Realtime Transfer Protocol) data on the IP-
PT side. This must be changed if another network application is using the same port.
For voice communications, an IP-PT uses 64 (with the IP-EXT16 card) or 16 (with the IP-EXT4 card)
contiguous UDP ports, starting from the port number specified here.
2.8 [1] Configuration
PC Programming Manual
311

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Kx-tda30Kx-tda200Kx-tda600

Table of Contents