Meridian Nortel 1 Option 11C Mini Installation Manual page 32

Planning and installation guide
Hide thumbs Also See for Nortel Meridian 1 Option 11C Mini:
Table of Contents

Advertisement

Page 32 of 332
Chapter 2 — Identifying the Option 11C Mini equipment
Table 1
Power supply DIP switch settings
Ringing Frequency (Hz)
20
25
Switch
Setting
1
ON
OFF
2
ON
ON
553-3021-209
Standard 3.00
Power switch
There is a power switch on the front of the NTDK91 Main Chassis and the
NTDK92 Chassis Expander. Use this switch to turn the Option 11C Mini
power on and off. See Figure 5 on page 34.
Power status indicator
There is a power status indicator (LED) on the front cover (top left-hand
corner) of the Main Chassis and the Chassis Expander. When the LED is
green, the power is in operation. When the LED is off, there is a power failure
of one of the power outputs. See Figure 5 on page 34.
Power supply DIP switch settings
Use a DIP switch to set ringing voltages, ringing frequencies, and message
waiting voltages. See Table 2 and Figure 5 on page 34 for all DIP switch
setting options. Typical settings are shown for the following regions:
"Asia Pacific/Cala power supply DIP switch settings" on page 33
"Europe power supply DIP switch settings" on page 33
"North American power supply DIP switch settings" on page 34
Ringing Amplitude (Vrms)
50
Switch
Setting
ON
3
OFF
4
5
April 2000
70
75
80
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
Message Waiting Lamp (VDC)
86
-120
Switch
Setting
ON
6
ON
7
OFF
ON
8
OFF
-150
Disable
NOT USED
OFF
ON
ON
X