Unit Assembly Prior To Installation; Flueing Introduction - Regency PG33-NG Owners & Installation

Table of Contents

Advertisement

The Top Facing Support, the Side Nailing Strips
and the 2 Top Standoffs must be correctly po-
sitioned and attached to the top before the unit
is put into position.
Top Standoff Assembly
The top standoffs are shipped in a flat position
and must be pulled up and bent into the cor-
rect shape.
1) Remove the standoffs from on top of the
firebox by undoing the screws.
2) Take each standoff and bend into the cor-
rect shape. Bend up at the bend lines until
the screw holes in the standoff and the
pre-punched screw holes on the firebox top
line-up.
3) Attach the standoffs securely to the top with
4 screws per standoff.
Note: Secure the standoffs to the holes
closest to the edge of the firebox top.
The PG33 uses the "balanced flue" technology Co Axial system. The inner liner flues products of combustion to the outside while the outer liner
draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm
room air up the chimney.
There are 2 flue systems approved for use with the PG33: the Regency Direct Flue System (Flex) for Horizontal Terminations only (see pages 11-
12), and the Simpson Dura-Flue Systems for Horizontal and Vertical Terminations (see pages 13-25).
Note: These flue pipes must not be connected to any other appliance.
The gas appliance and flue system must be flueed directly to the outside of the building, and never be attached to a chimney serving a separate
solid fuel or gas burning appliance. Each direct flue gas appliance must use it's own separate flue system. Common flue systems are prohibited.
NOTE: Ensure compliance with the outside flue terminal location before cutting hole as both dimensions must be met.
Regency PG33 Gas Inbuilt
UNIT ASSEMBLY
PRIOR TO INSTALLATION
Top Facing Support &
Side Nailing Strips
Determine the total thickness of facing mate-
rial (e.g. drywall plus ceramic tiles) to allow the
finished surface to be flush with the front of the
unit. Total facing thickness can vary from 1/2"
(13mm) to 1-1/4" (32mm) thick.
The Top Facing Support & Side Nailing Strips
can be mounted in various positions depending
on the thickness of the facing material.
1) Mount Top Facing Support using the 3
supplied screws into the three pre-punched
screw holes on the top front of the unit. Adjust
support to desired facing material depth.
2) Mount Side Nailing Strip using the 3 supplied
screws into the three pre-punched screw
holes at the front sides of the unit. Adjust
support to desired facing material thickness.

FLUEING INTRODUCTION

INSTALLATION
Top Facing
Support
For a facing material depth of
1-1/4"(32mm), the top facing
support must be reversed.
Side
Nailing
Strips
(folded out)